Add missing CHAMBER options (for M141) (#13371)
This commit is contained in:
		
				
					committed by
					
						 Scott Lahteine
						Scott Lahteine
					
				
			
			
				
	
			
			
			
						parent
						
							0375e92847
						
					
				
				
					commit
					31ff7da7ac
				
			| @@ -415,6 +415,8 @@ | ||||
| #define TEMP_BED_WINDOW          1  // (°C) Temperature proximity for the "temperature reached" timer | ||||
| #define TEMP_BED_HYSTERESIS      3  // (°C) Temperature proximity considered "close enough" to the target | ||||
|  | ||||
| #define TEMP_CHAMBER_HYSTERESIS  3  // (°C) Temperature proximity considered "close enough" to the target | ||||
|  | ||||
| // Below this temperature the heater will be switched off | ||||
| // because it probably indicates a broken thermistor wire. | ||||
| #define HEATER_0_MINTEMP   5 | ||||
| @@ -424,6 +426,7 @@ | ||||
| #define HEATER_4_MINTEMP   5 | ||||
| #define HEATER_5_MINTEMP   5 | ||||
| #define BED_MINTEMP        5 | ||||
| #define CHAMBER_MINTEMP    5 | ||||
|  | ||||
| // Above this temperature the heater will be switched off. | ||||
| // This can protect components from overheating, but NOT from shorts and failures. | ||||
| @@ -435,6 +438,7 @@ | ||||
| #define HEATER_4_MAXTEMP 275 | ||||
| #define HEATER_5_MAXTEMP 275 | ||||
| #define BED_MAXTEMP      150 | ||||
| #define CHAMBER_MAXTEMP  100 | ||||
|  | ||||
| //=========================================================================== | ||||
| //============================= PID Settings ================================ | ||||
|   | ||||
		Reference in New Issue
	