Start of process to get UBL running again.
The wait_for_user change totally broke UBL. But there is stuff wrong now in the thermal code and/or LCD Panel code.
This commit is contained in:
@@ -594,18 +594,18 @@
|
||||
save_ubl_active_state_and_disable();
|
||||
//measured_z = probe_pt(x_pos + X_PROBE_OFFSET_FROM_EXTRUDER, y_pos + Y_PROBE_OFFSET_FROM_EXTRUDER, ProbeDeployAndStow, g29_verbose_level);
|
||||
|
||||
ubl_has_control_of_lcd_panel = true;// Grab the LCD Hardware
|
||||
measured_z = 1.5;
|
||||
do_blocking_move_to_z(measured_z); // Get close to the bed, but leave some space so we don't damage anything
|
||||
// The user is not going to be locking in a new Z-Offset very often so
|
||||
// it won't be that painful to spin the Encoder Wheel for 1.5mm
|
||||
lcd_implementation_clear();
|
||||
lcd_z_offset_edit_setup(measured_z);
|
||||
wait_for_user = true;
|
||||
do {
|
||||
measured_z = lcd_z_offset_edit();
|
||||
idle();
|
||||
do_blocking_move_to_z(measured_z);
|
||||
} while (wait_for_user);
|
||||
} while (!ubl_lcd_clicked());
|
||||
|
||||
ubl_has_control_of_lcd_panel++; // There is a race condition for the Encoder Wheel getting clicked.
|
||||
// It could get detected in lcd_mesh_edit (actually _lcd_mesh_fine_tune)
|
||||
@@ -707,14 +707,17 @@
|
||||
save_ubl_active_state_and_disable(); // we don't do bed level correction because we want the raw data when we probe
|
||||
DEPLOY_PROBE();
|
||||
|
||||
wait_for_user = true;
|
||||
do {
|
||||
if (!wait_for_user) {
|
||||
SERIAL_PROTOCOLLNPGM("\nMesh only partially populated.");
|
||||
if (ubl_lcd_clicked()) {
|
||||
SERIAL_PROTOCOLLNPGM("\nMesh only partially populated.\n");
|
||||
lcd_quick_feedback();
|
||||
ubl_has_control_of_lcd_panel = false;
|
||||
STOW_PROBE();
|
||||
while (ubl_lcd_clicked() ) {
|
||||
idle();
|
||||
}
|
||||
ubl_has_control_of_lcd_panel = false;
|
||||
restore_ubl_active_state_and_leave();
|
||||
delay(50); // Debounce the Encoder wheel
|
||||
return;
|
||||
}
|
||||
|
||||
@@ -737,7 +740,6 @@
|
||||
|
||||
LEAVE:
|
||||
|
||||
wait_for_user = false;
|
||||
STOW_PROBE();
|
||||
restore_ubl_active_state_and_leave();
|
||||
|
||||
@@ -813,8 +815,7 @@
|
||||
}
|
||||
|
||||
float use_encoder_wheel_to_measure_point() {
|
||||
wait_for_user = true;
|
||||
while (wait_for_user) { // we need the loop to move the nozzle based on the encoder wheel here!
|
||||
while (!ubl_lcd_clicked()) { // we need the loop to move the nozzle based on the encoder wheel here!
|
||||
idle();
|
||||
if (ubl_encoderDiff) {
|
||||
do_blocking_move_to_z(current_position[Z_AXIS] + 0.01 * float(ubl_encoderDiff));
|
||||
@@ -891,8 +892,8 @@
|
||||
last_x = xProbe;
|
||||
last_y = yProbe;
|
||||
|
||||
wait_for_user = true;
|
||||
while (wait_for_user) { // we need the loop to move the nozzle based on the encoder wheel here!
|
||||
ubl_has_control_of_lcd_panel = true;
|
||||
while (!ubl_lcd_clicked) { // we need the loop to move the nozzle based on the encoder wheel here!
|
||||
idle();
|
||||
if (ubl_encoderDiff) {
|
||||
do_blocking_move_to_z(current_position[Z_AXIS] + float(ubl_encoderDiff) / 100.0);
|
||||
|
Reference in New Issue
Block a user