README and Version for 1.1.0-RC8

This commit is contained in:
Scott Lahteine
2016-12-06 00:46:35 -06:00
parent 87d89b8cc9
commit c69f213ae8
2 changed files with 24 additions and 3 deletions

View File

@@ -35,7 +35,7 @@
/**
* Marlin release version identifier
*/
#define SHORT_BUILD_VERSION "1.1.0-RC7"
#define SHORT_BUILD_VERSION "1.1.0-RC8"
/**
* Verbose version identifier which should contain a reference to the location
@@ -48,7 +48,7 @@
* here we define this default string as the date where the latest release
* version was tagged.
*/
#define STRING_DISTRIBUTION_DATE "2016-07-31 12:00"
#define STRING_DISTRIBUTION_DATE "2016-12-06 12:00"
/**
* Required minimum Configuration.h and Configuration_adv.h file versions.

View File

@@ -5,7 +5,7 @@
Additional documentation can be found at [The Marlin Documentation Project](https://www.marlinfw.org/).
Please test this firmware and inform us if it misbehaves in any way, volunteers are standing by!
## Release Candidate -- Marlin 1.1.0-RC7 - 31 July 2016
## Release Candidate -- Marlin 1.1.0-RC8 - 6 Dec 2016
__Not for production use use with caution!__
@@ -14,6 +14,27 @@ You can download earlier versions of Marlin on the [Releases page](https://githu
The latest Release Candidate lives in the ["RC" branch](https://github.com/MarlinFirmware/Marlin/tree/RC). Bugs that we find in the current Release Candidate are patched in the ["RCBugFix" branch](https://github.com/MarlinFirmware/Marlin/tree/RCBugFix), so during beta testing this is where you can always find the latest code on its way towards release.
## Recent Changes
- RC8 - 06 Dec 2016
- Major performance improvement for Graphical LCDs
- Simplified probe configuration
- Enable Auto Bed Leveling by type
- Reduce serial communication errors
- Make Bilinear (Mesh) Grid Leveling available for non-delta
- Support for Trinamic TMC2130 SilentStepStick SPI-based drivers
- Add `M211` to Enable/Disable Software Endstops
- Add `M355` to turn the case light on/off and set brightness
- Improved I2C class with full master/slave support
- Add `G38.2` `G38.3` command option for CNC style probing
- Add `MINIMUM_STEPPER_PULSE` option to adjust step pulse duration
- Add `R` parameter support for `G2`/`G3`
- Add `M43` optional command (`PINS_DEBUGGING`)
- Remove SCARA axis scaling
- Improved sanity checking of configuration
- Improved support for PlatformIO and command-line build
- Usable `DELTA_CALIBRATION_MENU`
- Support for Printrbot Rev.F
- New and updated languages
- RC7 - 31 Jul 2016
- Add Print Job Timer and Print Counter (`PRINTCOUNTER`)
- New `M600` Filament Change (`FILAMENT_CHANGE_FEATURE`)