Limit top bed temp to BED_MAXTEMP - 10

The chances of a 10° overshoot is pretty minimal.
This commit is contained in:
Scott Lahteine
2019-03-11 16:32:34 -05:00
parent 98b55421a5
commit e52bcc9408
8 changed files with 9 additions and 9 deletions

View File

@ -143,7 +143,7 @@ void menu_tune() {
// Bed:
//
#if HAS_HEATED_BED
MENU_MULTIPLIER_ITEM_EDIT_CALLBACK(int3, MSG_BED, &thermalManager.temp_bed.target, 0, BED_MAXTEMP - 15, thermalManager.start_watching_bed);
MENU_MULTIPLIER_ITEM_EDIT_CALLBACK(int3, MSG_BED, &thermalManager.temp_bed.target, 0, BED_MAXTEMP - 10, thermalManager.start_watching_bed);
#endif
//