Correct analog sampling time for additional A to D sample
Adjusted the #define PID_dT to reflect 10 A to D sample steps, vs original 8.
This commit is contained in:
		@@ -185,7 +185,7 @@
 | 
			
		||||
                                  // is more then PID_FUNCTIONAL_RANGE then the PID will be shut off and the heater will be set to min/max.
 | 
			
		||||
  #define PID_INTEGRAL_DRIVE_MAX 255  //limit for the integral term
 | 
			
		||||
  #define K1 0.95 //smoothing factor within the PID
 | 
			
		||||
  #define PID_dT ((OVERSAMPLENR * 8.0)/(F_CPU / 64.0 / 256.0)) //sampling period of the temperature routine
 | 
			
		||||
  #define PID_dT ((OVERSAMPLENR * 10.0)/(F_CPU / 64.0 / 256.0)) //sampling period of the temperature routine
 | 
			
		||||
 | 
			
		||||