From 2b030e54fd32c53512ba473503e6de7c8cd05d83 Mon Sep 17 00:00:00 2001 From: Tim Crawford Date: Tue, 19 Jul 2022 09:00:37 -0600 Subject: [PATCH] mb/system76/adl-p: oryp9: Adjust power limits again - Limit PL4 to 72W (1.6x TDP) - Increase PL2 back to coreboot default value of 115W - Increase PsysPL2 to 135W Change-Id: I6d25a92d523d1d73dc6cdea6b630a47a832a54b6 Signed-off-by: Tim Crawford --- src/mainboard/system76/adl-p/variants/oryp9/overridetree.cb | 6 +++--- 1 file changed, 3 insertions(+), 3 deletions(-) diff --git a/src/mainboard/system76/adl-p/variants/oryp9/overridetree.cb b/src/mainboard/system76/adl-p/variants/oryp9/overridetree.cb index be334209fa..985303afc0 100644 --- a/src/mainboard/system76/adl-p/variants/oryp9/overridetree.cb +++ b/src/mainboard/system76/adl-p/variants/oryp9/overridetree.cb @@ -3,9 +3,9 @@ chip soc/intel/alderlake # EC will set PL4 on AC adapter plug/unplug register "power_limits_config[ADL_P_642_682_45W_CORE]" = "{ .tdp_pl1_override = 45, - .tdp_pl2_override = 90, - .tdp_psyspl2 = 115, - .tdp_pl4 = 115, + .tdp_pl2_override = 115, + .tdp_psyspl2 = 135, + .tdp_pl4 = 72, }" # Thermal