siemens/mc_apl1: Extend circuit life by clock gating and power gating
The firmware of devices connected to LPC should deassert the LPC CLKRUN# signal when there is no bus activity on LPC. Necessary changes: - Enable LPC CLKRUN# - Enable LPC PCE (Power Control Enable) - Enable LPC CCE (Clock Control Enable) - Remove I/O decoding range on LPC for COM 3 - Disable I/O UART driver Change-Id: I2fd80e3fdcf23658f97b8182a77df7e09ddf25d6 Signed-off-by: Mario Scheithauer <mario.scheithauer@siemens.com> Reviewed-on: https://review.coreboot.org/28268 Tested-by: build bot (Jenkins) <no-reply@coreboot.org> Reviewed-by: Werner Zeh <werner.zeh@siemens.com> Reviewed-by: Paul Menzel <paulepanter@users.sourceforge.net>
This commit is contained in:
committed by
Martin Roth
parent
24ad29e83c
commit
403458e7ec
@@ -2,6 +2,7 @@
|
||||
* This file is part of the coreboot project.
|
||||
*
|
||||
* Copyright 2017 Intel Corporation.
|
||||
* Copyright (C) 2018 Siemens AG
|
||||
*
|
||||
* This program is free software; you can redistribute it and/or modify
|
||||
* it under the terms of the GNU General Public License as published by
|
||||
@@ -31,6 +32,7 @@
|
||||
#define PID_GPIO_N 0xC5
|
||||
#define PID_ITSS 0xD0
|
||||
#define PID_RTC 0xD1
|
||||
#define PID_LPC 0xD2
|
||||
|
||||
#define PID_AUNIT 0x4d
|
||||
#define PID_BUNIT 0x4c
|
||||
|
Reference in New Issue
Block a user