mb/siemens/mc_ehl3/lcd_panel.c: Set LVDS re-power delay to 1 s
The currently used panel type could work with 500 ms but increasing the value to 1 second allows to use a wider range of LVDS LCD panels, as many of them specify the delay of 1 s as minimum. BUG=none TEST=Test link stability using a panel with minimum re-power delay of 1 s. Change-Id: I2dd86e791c1212b67a80d7e6cfc474ad91b26c6b Signed-off-by: Jan Samek <jan.samek@siemens.com> Reviewed-on: https://review.coreboot.org/c/coreboot/+/72804 Tested-by: build bot (Jenkins) <no-reply@coreboot.org> Reviewed-by: Werner Zeh <werner.zeh@siemens.com>
This commit is contained in:
		| @@ -82,8 +82,8 @@ enum cb_err mb_adjust_cfg(struct ptn_3460_config *cfg) | ||||
| 	cfg->t2_delay = 0x01; | ||||
| 	/* LVDS to backlight active delay: 200 ms */ | ||||
| 	cfg->t3_timing = 0x04; | ||||
| 	/* Minimum re-power delay: 500 ms */ | ||||
| 	cfg->t12_timing = 0x0a; | ||||
| 	/* Minimum re-power delay: 1 s */ | ||||
| 	cfg->t12_timing = 0x14; | ||||
| 	/* Backlight off to LVDS inactive delay: 200 ms */ | ||||
| 	cfg->t4_timing = 0x04; | ||||
| 	/* Enable LVDS to VDD inactive delay. */ | ||||
|   | ||||