Generated 'build/dsdt.dsl' files are same. Change-Id: I85edf649a5170a1658fb135b797c1c6e1d2a9d70 Signed-off-by: Elyes HAOUAS <ehaouas@noos.fr> Reviewed-on: https://review.coreboot.org/c/coreboot/+/46171 Tested-by: build bot (Jenkins) <no-reply@coreboot.org> Reviewed-by: Michael Niewöhner <foss@mniewoehner.de>
67 lines
1.1 KiB
Plaintext
67 lines
1.1 KiB
Plaintext
/* SPDX-License-Identifier: GPL-2.0-only */
|
|
|
|
// Thermal Zone
|
|
|
|
External (\PPKG, MethodObj)
|
|
|
|
#define HAVE_THERMALZONE
|
|
Scope (\_TZ)
|
|
{
|
|
ThermalZone (THRM)
|
|
{
|
|
Name (_TC1, 0x02)
|
|
Name (_TC2, 0x05)
|
|
|
|
// Thermal zone polling frequency: 10 seconds
|
|
Name (_TZP, 100)
|
|
|
|
// Thermal sampling period for passive cooling: 2 seconds
|
|
Name (_TSP, 20)
|
|
|
|
// Convert from Degrees C to 1/10 Kelvin for ACPI
|
|
Method (CTOK, 1) {
|
|
// 10th of Degrees C
|
|
Local0 = Arg0 * 10
|
|
|
|
// Convert to Kelvin
|
|
Local0 += 2732
|
|
|
|
Return (Local0)
|
|
}
|
|
|
|
// Threshold for OS to shutdown
|
|
Method (_CRT, 0, Serialized)
|
|
{
|
|
Return (CTOK (\TCRT))
|
|
}
|
|
|
|
// Threshold for passive cooling
|
|
Method (_PSV, 0, Serialized)
|
|
{
|
|
Return (CTOK (\TPSV))
|
|
}
|
|
|
|
// Processors used for passive cooling
|
|
Method (_PSL, 0, Serialized)
|
|
{
|
|
Return (\PPKG ())
|
|
}
|
|
|
|
Method (_TMP, 0, Serialized)
|
|
{
|
|
// Get CPU Temperature from EC
|
|
Local0 = \_SB.PCI0.LPCB.EC0.CTMP
|
|
|
|
// Convert to 1/10 Kelvin
|
|
Local0 *= 10
|
|
|
|
// Adjust by offset to get Kelvin
|
|
Local0 += 2732
|
|
|
|
Return (Local0)
|
|
}
|
|
|
|
// The EC does all fan control. There is no Active Cooling Fan control (_ACx).
|
|
}
|
|
}
|