diff --git a/edksetup.bat b/edksetup.bat index 2c8c072884..6e526cdd03 100755 --- a/edksetup.bat +++ b/edksetup.bat @@ -31,12 +31,12 @@ pushd . cd %~dp0 if not defined WORKSPACE ( - @goto SetWorkSpace + goto SetWorkSpace ) if %WORKSPACE% == %CD% ( @REM Workspace is not changed. - @goto ParseArgs + goto ParseArgs ) :SetWorkSpace @@ -47,14 +47,14 @@ set EFI_SOURCE= set EDK_SOURCE= :ParseArgs -@if /I "%1"=="-h" goto Usage -@if /I "%1"=="-help" goto Usage -@if /I "%1"=="--help" goto Usage -@if /I "%1"=="/h" goto Usage -@if /I "%1"=="/?" goto Usage -@if /I "%1"=="/help" goto Usage +if /I "%1"=="-h" goto Usage +if /I "%1"=="-help" goto Usage +if /I "%1"=="--help" goto Usage +if /I "%1"=="/h" goto Usage +if /I "%1"=="/?" goto Usage +if /I "%1"=="/help" goto Usage -@if /I not "%1"=="--nt32" goto no_nt32 +if /I not "%1"=="--nt32" goto no_nt32 @REM Flag, --nt32 is set @REM The Nt32 Emluation Platform requires Microsoft Libraries @@ -88,38 +88,38 @@ if not defined VCINSTALLDIR ( shift :no_nt32 -@if /I "%1"=="NewBuild" shift -@if not defined EDK_TOOLS_PATH set EDK_TOOLS_PATH=%WORKSPACE%\BaseTools -@IF NOT EXIST "%EDK_TOOLS_PATH%\toolsetup.bat" goto BadBaseTools -@call %EDK_TOOLS_PATH%\toolsetup.bat %* -@if /I "%1"=="Reconfig" shift -@goto check_cygwin +if /I "%1"=="NewBuild" shift +if not defined EDK_TOOLS_PATH set EDK_TOOLS_PATH=%WORKSPACE%\BaseTools +IF NOT EXIST "%EDK_TOOLS_PATH%\toolsetup.bat" goto BadBaseTools +call %EDK_TOOLS_PATH%\toolsetup.bat %* +if /I "%1"=="Reconfig" shift +goto check_cygwin :BadBaseTools @REM - @REM Need the BaseTools Package in order to build + REM Need the BaseTools Package in order to build @REM - echo. - echo !!! ERROR !!! The BaseTools Package was not found !!! - echo. - echo Set the system environment variable, EDK_TOOLS_PATH to the BaseTools, - echo For example, - echo set EDK_TOOLS_PATH=C:\MyTools\BaseTools - echo The setup script, toolsetup.bat must reside in this folder. - echo. - @goto end + @echo. + @echo !!! ERROR !!! The BaseTools Package was not found !!! + @echo. + @echo Set the system environment variable, EDK_TOOLS_PATH to the BaseTools, + @echo For example, + @echo set EDK_TOOLS_PATH=C:\MyTools\BaseTools + @echo The setup script, toolsetup.bat must reside in this folder. + @echo. + goto end :check_cygwin - @if exist c:\cygwin ( - @set CYGWIN_HOME=c:\cygwin + if exist c:\cygwin ( + set CYGWIN_HOME=c:\cygwin ) else ( @echo. @echo !!! WARNING !!! No CYGWIN_HOME set, gcc build may not be used !!! @echo. ) -@if NOT "%1"=="" goto Usage -@goto end +if NOT "%1"=="" goto Usage +goto end :Usage @echo. @@ -132,9 +132,8 @@ shift @echo will be only copied to target.txt, tools_def.txt and build_rule.txt @echo respectively if they do not exist. Using option [Reconfig] to force the copy. @echo. - @goto end + goto end :end - @popd - @echo on + popd