BaseTools: refactor the error for PCD value is negative or exceed max

refactor the error handling for the PCD value that is negative or it
exceed the max value.

Cc: Liming Gao <liming.gao@intel.com>
Cc: Yonghong Zhu <yonghong.zhu@intel.com>
Contributed-under: TianoCore Contribution Agreement 1.1
Signed-off-by: Zhiju.Fan <zhijux.fan@intel.com>
Reviewed-by: Yonghong Zhu <yonghong.zhu@intel.com>
This commit is contained in:
zhijufan
2018-09-27 14:08:15 +08:00
committed by Yonghong Zhu
parent 5b02be4d9a
commit c526dcd40f
3 changed files with 30 additions and 75 deletions

View File

@ -1015,50 +1015,19 @@ def CreateModulePcdCode(Info, AutoGenC, AutoGenH, Pcd):
EdkLogger.error("build", AUTOGEN_ERROR,
"PCD value is not valid dec or hex number for datum type [%s] of PCD %s.%s" % (Pcd.DatumType, Pcd.TokenSpaceGuidCName, TokenCName),
ExtraData="[%s]" % str(Info))
if Pcd.DatumType == TAB_UINT64:
if ValueNumber < 0:
EdkLogger.error("build", AUTOGEN_ERROR,
"PCD can't be set to negative value for datum type [%s] of PCD %s.%s" % (Pcd.DatumType, Pcd.TokenSpaceGuidCName, TokenCName),
ExtraData="[%s]" % str(Info))
elif ValueNumber >= 0x10000000000000000:
EdkLogger.error("build", AUTOGEN_ERROR,
"Too large PCD value for datum type [%s] of PCD %s.%s" % (Pcd.DatumType, Pcd.TokenSpaceGuidCName, TokenCName),
ExtraData="[%s]" % str(Info))
if not Value.endswith('ULL'):
Value += 'ULL'
elif Pcd.DatumType == TAB_UINT32:
if ValueNumber < 0:
EdkLogger.error("build", AUTOGEN_ERROR,
"PCD can't be set to negative value for datum type [%s] of PCD %s.%s" % (Pcd.DatumType, Pcd.TokenSpaceGuidCName, TokenCName),
ExtraData="[%s]" % str(Info))
elif ValueNumber >= 0x100000000:
EdkLogger.error("build", AUTOGEN_ERROR,
"Too large PCD value for datum type [%s] of PCD %s.%s" % (Pcd.DatumType, Pcd.TokenSpaceGuidCName, TokenCName),
ExtraData="[%s]" % str(Info))
if not Value.endswith('U'):
Value += 'U'
elif Pcd.DatumType == TAB_UINT16:
if ValueNumber < 0:
EdkLogger.error("build", AUTOGEN_ERROR,
"PCD can't be set to negative value for datum type [%s] of PCD %s.%s" % (Pcd.DatumType, Pcd.TokenSpaceGuidCName, TokenCName),
ExtraData="[%s]" % str(Info))
elif ValueNumber >= 0x10000:
EdkLogger.error("build", AUTOGEN_ERROR,
"Too large PCD value for datum type [%s] of PCD %s.%s" % (Pcd.DatumType, Pcd.TokenSpaceGuidCName, TokenCName),
ExtraData="[%s]" % str(Info))
if not Value.endswith('U'):
Value += 'U'
elif Pcd.DatumType == TAB_UINT8:
if ValueNumber < 0:
EdkLogger.error("build", AUTOGEN_ERROR,
"PCD can't be set to negative value for datum type [%s] of PCD %s.%s" % (Pcd.DatumType, Pcd.TokenSpaceGuidCName, TokenCName),
ExtraData="[%s]" % str(Info))
elif ValueNumber >= 0x100:
EdkLogger.error("build", AUTOGEN_ERROR,
"Too large PCD value for datum type [%s] of PCD %s.%s" % (Pcd.DatumType, Pcd.TokenSpaceGuidCName, TokenCName),
ExtraData="[%s]" % str(Info))
if not Value.endswith('U'):
Value += 'U'
if ValueNumber < 0:
EdkLogger.error("build", AUTOGEN_ERROR,
"PCD can't be set to negative value for datum type [%s] of PCD %s.%s" % (Pcd.DatumType, Pcd.TokenSpaceGuidCName, TokenCName),
ExtraData="[%s]" % str(Info))
elif ValueNumber > MAX_VAL_TYPE[Pcd.DatumType]:
EdkLogger.error("build", AUTOGEN_ERROR,
"Too large PCD value for datum type [%s] of PCD %s.%s" % (Pcd.DatumType, Pcd.TokenSpaceGuidCName, TokenCName),
ExtraData="[%s]" % str(Info))
if Pcd.DatumType == TAB_UINT64 and not Value.endswith('ULL'):
Value += 'ULL'
elif Pcd.DatumType != TAB_UINT64 and not Value.endswith('U'):
Value += 'U'
if Pcd.DatumType not in TAB_PCD_NUMERIC_TYPES:
if not Pcd.MaxDatumSize:
EdkLogger.error("build", AUTOGEN_ERROR,