BaseTools: Adjust the spaces around commas and colons

Based on "futurize -f lib2to3.fixes.fix_ws_comma"

Contributed-under: TianoCore Contribution Agreement 1.1
Cc: Yonghong Zhu <yonghong.zhu@intel.com>
Cc: Liming Gao <liming.gao@intel.com>
Signed-off-by: Gary Lin <glin@suse.com>
Reviewed-by: Yonghong Zhu <yonghong.zhu@intel.com>
This commit is contained in:
Gary Lin
2018-06-25 18:31:33 +08:00
committed by Yonghong Zhu
parent df29fd130a
commit ccaa7754a2
57 changed files with 543 additions and 543 deletions

View File

@ -48,7 +48,7 @@ from Common.MultipleWorkspace import MultipleWorkspace as mws
import InfSectionParser
import datetime
import hashlib
from GenVar import VariableMgr,var_info
from GenVar import VariableMgr, var_info
from collections import OrderedDict
from collections import defaultdict
from Workspace.WorkspaceCommon import OrderedListDict
@ -1293,7 +1293,7 @@ class PlatformAutoGen(AutoGen):
ShareFixedAtBuildPcdsSameValue = {}
for Module in LibAuto._ReferenceModules:
for Pcd in Module.FixedAtBuildPcds + LibAuto.FixedAtBuildPcds:
key = ".".join((Pcd.TokenSpaceGuidCName,Pcd.TokenCName))
key = ".".join((Pcd.TokenSpaceGuidCName, Pcd.TokenCName))
if key not in FixedAtBuildPcds:
ShareFixedAtBuildPcdsSameValue[key] = True
FixedAtBuildPcds[key] = Pcd.DefaultValue
@ -1301,11 +1301,11 @@ class PlatformAutoGen(AutoGen):
if FixedAtBuildPcds[key] != Pcd.DefaultValue:
ShareFixedAtBuildPcdsSameValue[key] = False
for Pcd in LibAuto.FixedAtBuildPcds:
key = ".".join((Pcd.TokenSpaceGuidCName,Pcd.TokenCName))
if (Pcd.TokenCName,Pcd.TokenSpaceGuidCName) not in self.NonDynamicPcdDict:
key = ".".join((Pcd.TokenSpaceGuidCName, Pcd.TokenCName))
if (Pcd.TokenCName, Pcd.TokenSpaceGuidCName) not in self.NonDynamicPcdDict:
continue
else:
DscPcd = self.NonDynamicPcdDict[(Pcd.TokenCName,Pcd.TokenSpaceGuidCName)]
DscPcd = self.NonDynamicPcdDict[(Pcd.TokenCName, Pcd.TokenSpaceGuidCName)]
if DscPcd.Type != TAB_PCDS_FIXED_AT_BUILD:
continue
if key in ShareFixedAtBuildPcdsSameValue and ShareFixedAtBuildPcdsSameValue[key]:
@ -1325,12 +1325,12 @@ class PlatformAutoGen(AutoGen):
break
VariableInfo = VariableMgr(self.DscBuildDataObj._GetDefaultStores(),self.DscBuildDataObj._GetSkuIds())
VariableInfo = VariableMgr(self.DscBuildDataObj._GetDefaultStores(), self.DscBuildDataObj._GetSkuIds())
VariableInfo.SetVpdRegionMaxSize(VpdRegionSize)
VariableInfo.SetVpdRegionOffset(VpdRegionBase)
Index = 0
for Pcd in DynamicPcdSet:
pcdname = ".".join((Pcd.TokenSpaceGuidCName,Pcd.TokenCName))
pcdname = ".".join((Pcd.TokenSpaceGuidCName, Pcd.TokenCName))
for SkuName in Pcd.SkuInfoList:
Sku = Pcd.SkuInfoList[SkuName]
SkuId = Sku.SkuId
@ -1340,11 +1340,11 @@ class PlatformAutoGen(AutoGen):
VariableGuidStructure = Sku.VariableGuidValue
VariableGuid = GuidStructureStringToGuidString(VariableGuidStructure)
for StorageName in Sku.DefaultStoreDict:
VariableInfo.append_variable(var_info(Index,pcdname,StorageName,SkuName, StringToArray(Sku.VariableName),VariableGuid, Sku.VariableOffset, Sku.VariableAttribute , Sku.HiiDefaultValue,Sku.DefaultStoreDict[StorageName],Pcd.DatumType))
VariableInfo.append_variable(var_info(Index, pcdname, StorageName, SkuName, StringToArray(Sku.VariableName), VariableGuid, Sku.VariableOffset, Sku.VariableAttribute, Sku.HiiDefaultValue, Sku.DefaultStoreDict[StorageName], Pcd.DatumType))
Index += 1
return VariableInfo
def UpdateNVStoreMaxSize(self,OrgVpdFile):
def UpdateNVStoreMaxSize(self, OrgVpdFile):
if self.VariableInfo:
VpdMapFilePath = os.path.join(self.BuildDir, TAB_FV_DIRECTORY, "%s.map" % self.Platform.VpdToolGuid)
PcdNvStoreDfBuffer = [item for item in self._DynamicPcdList if item.TokenCName == "PcdNvStoreDefaultValueBuffer" and item.TokenSpaceGuidCName == "gEfiMdeModulePkgTokenSpaceGuid"]
@ -1357,7 +1357,7 @@ class PlatformAutoGen(AutoGen):
else:
EdkLogger.error("build", FILE_READ_FAILURE, "Can not find VPD map file %s to fix up VPD offset." % VpdMapFilePath)
NvStoreOffset = int(NvStoreOffset,16) if NvStoreOffset.upper().startswith("0X") else int(NvStoreOffset)
NvStoreOffset = int(NvStoreOffset, 16) if NvStoreOffset.upper().startswith("0X") else int(NvStoreOffset)
default_skuobj = PcdNvStoreDfBuffer[0].SkuInfoList.get(TAB_DEFAULT)
maxsize = self.VariableInfo.VpdRegionSize - NvStoreOffset if self.VariableInfo.VpdRegionSize else len(default_skuobj.DefaultValue.split(","))
var_data = self.VariableInfo.PatchNVStoreDefaultMaxSize(maxsize)
@ -1569,7 +1569,7 @@ class PlatformAutoGen(AutoGen):
VpdPcdDict[(Pcd.TokenCName, Pcd.TokenSpaceGuidCName)] = Pcd
#Collect DynamicHii PCD values and assign it to DynamicExVpd PCD gEfiMdeModulePkgTokenSpaceGuid.PcdNvStoreDefaultValueBuffer
PcdNvStoreDfBuffer = VpdPcdDict.get(("PcdNvStoreDefaultValueBuffer","gEfiMdeModulePkgTokenSpaceGuid"))
PcdNvStoreDfBuffer = VpdPcdDict.get(("PcdNvStoreDefaultValueBuffer", "gEfiMdeModulePkgTokenSpaceGuid"))
if PcdNvStoreDfBuffer:
self.VariableInfo = self.CollectVariables(self._DynamicPcdList)
vardump = self.VariableInfo.dump()
@ -1595,10 +1595,10 @@ class PlatformAutoGen(AutoGen):
PcdValue = DefaultSku.DefaultValue
if PcdValue not in SkuValueMap:
SkuValueMap[PcdValue] = []
VpdFile.Add(Pcd, TAB_DEFAULT,DefaultSku.VpdOffset)
VpdFile.Add(Pcd, TAB_DEFAULT, DefaultSku.VpdOffset)
SkuValueMap[PcdValue].append(DefaultSku)
for (SkuName,Sku) in Pcd.SkuInfoList.items():
for (SkuName, Sku) in Pcd.SkuInfoList.items():
Sku.VpdOffset = Sku.VpdOffset.strip()
PcdValue = Sku.DefaultValue
if PcdValue == "":
@ -1624,7 +1624,7 @@ class PlatformAutoGen(AutoGen):
EdkLogger.error("build", FORMAT_INVALID, 'The offset value of PCD %s.%s should be %s-byte aligned.' % (Pcd.TokenSpaceGuidCName, Pcd.TokenCName, Alignment))
if PcdValue not in SkuValueMap:
SkuValueMap[PcdValue] = []
VpdFile.Add(Pcd, SkuName,Sku.VpdOffset)
VpdFile.Add(Pcd, SkuName, Sku.VpdOffset)
SkuValueMap[PcdValue].append(Sku)
# if the offset of a VPD is *, then it need to be fixed up by third party tool.
if not NeedProcessVpdMapFile and Sku.VpdOffset == "*":
@ -1656,9 +1656,9 @@ class PlatformAutoGen(AutoGen):
SkuObjList = DscPcdEntry.SkuInfoList.items()
DefaultSku = DscPcdEntry.SkuInfoList.get(TAB_DEFAULT)
if DefaultSku:
defaultindex = SkuObjList.index((TAB_DEFAULT,DefaultSku))
SkuObjList[0],SkuObjList[defaultindex] = SkuObjList[defaultindex],SkuObjList[0]
for (SkuName,Sku) in SkuObjList:
defaultindex = SkuObjList.index((TAB_DEFAULT, DefaultSku))
SkuObjList[0], SkuObjList[defaultindex] = SkuObjList[defaultindex], SkuObjList[0]
for (SkuName, Sku) in SkuObjList:
Sku.VpdOffset = Sku.VpdOffset.strip()
# Need to iterate DEC pcd information to get the value & datumtype
@ -1708,7 +1708,7 @@ class PlatformAutoGen(AutoGen):
EdkLogger.error("build", FORMAT_INVALID, 'The offset value of PCD %s.%s should be %s-byte aligned.' % (DscPcdEntry.TokenSpaceGuidCName, DscPcdEntry.TokenCName, Alignment))
if PcdValue not in SkuValueMap:
SkuValueMap[PcdValue] = []
VpdFile.Add(DscPcdEntry, SkuName,Sku.VpdOffset)
VpdFile.Add(DscPcdEntry, SkuName, Sku.VpdOffset)
SkuValueMap[PcdValue].append(Sku)
if not NeedProcessVpdMapFile and Sku.VpdOffset == "*":
NeedProcessVpdMapFile = True
@ -1774,17 +1774,17 @@ class PlatformAutoGen(AutoGen):
self._DynamicPcdList.extend(list(UnicodePcdArray))
self._DynamicPcdList.extend(list(HiiPcdArray))
self._DynamicPcdList.extend(list(OtherPcdArray))
allskuset = [(SkuName,Sku.SkuId) for pcd in self._DynamicPcdList for (SkuName,Sku) in pcd.SkuInfoList.items()]
allskuset = [(SkuName, Sku.SkuId) for pcd in self._DynamicPcdList for (SkuName, Sku) in pcd.SkuInfoList.items()]
for pcd in self._DynamicPcdList:
if len(pcd.SkuInfoList) == 1:
for (SkuName,SkuId) in allskuset:
if type(SkuId) in (str,unicode) and eval(SkuId) == 0 or SkuId == 0:
for (SkuName, SkuId) in allskuset:
if type(SkuId) in (str, unicode) and eval(SkuId) == 0 or SkuId == 0:
continue
pcd.SkuInfoList[SkuName] = copy.deepcopy(pcd.SkuInfoList[TAB_DEFAULT])
pcd.SkuInfoList[SkuName].SkuId = SkuId
self.AllPcdList = self._NonDynamicPcdList + self._DynamicPcdList
def FixVpdOffset(self,VpdFile ):
def FixVpdOffset(self, VpdFile ):
FvPath = os.path.join(self.BuildDir, TAB_FV_DIRECTORY)
if not os.path.exists(FvPath):
try:
@ -2050,7 +2050,7 @@ class PlatformAutoGen(AutoGen):
if self._NonDynamicPcdDict:
return self._NonDynamicPcdDict
for Pcd in self.NonDynamicPcdList:
self._NonDynamicPcdDict[(Pcd.TokenCName,Pcd.TokenSpaceGuidCName)] = Pcd
self._NonDynamicPcdDict[(Pcd.TokenCName, Pcd.TokenSpaceGuidCName)] = Pcd
return self._NonDynamicPcdDict
## Get list of non-dynamic PCDs
@ -3711,7 +3711,7 @@ class ModuleAutoGen(AutoGen):
try:
fInputfile = open(UniVfrOffsetFileName, "wb+", 0)
except:
EdkLogger.error("build", FILE_OPEN_FAILURE, "File open failed for %s" % UniVfrOffsetFileName,None)
EdkLogger.error("build", FILE_OPEN_FAILURE, "File open failed for %s" % UniVfrOffsetFileName, None)
# Use a instance of StringIO to cache data
fStringIO = StringIO('')
@ -3746,7 +3746,7 @@ class ModuleAutoGen(AutoGen):
fInputfile.write (fStringIO.getvalue())
except:
EdkLogger.error("build", FILE_WRITE_FAILURE, "Write data to file %s failed, please check whether the "
"file been locked or using by other applications." %UniVfrOffsetFileName,None)
"file been locked or using by other applications." %UniVfrOffsetFileName, None)
fStringIO.close ()
fInputfile.close ()
@ -4181,7 +4181,7 @@ class ModuleAutoGen(AutoGen):
def CopyBinaryFiles(self):
for File in self.Module.Binaries:
SrcPath = File.Path
DstPath = os.path.join(self.OutputDir , os.path.basename(SrcPath))
DstPath = os.path.join(self.OutputDir, os.path.basename(SrcPath))
CopyLongFilePath(SrcPath, DstPath)
## Create autogen code for the module and its dependent libraries
#
@ -4331,7 +4331,7 @@ class ModuleAutoGen(AutoGen):
if SrcTimeStamp > DstTimeStamp:
return False
with open(self.GetTimeStampPath(),'r') as f:
with open(self.GetTimeStampPath(), 'r') as f:
for source in f:
source = source.rstrip('\n')
if not os.path.exists(source):