If Structure PCD and Normal Pcd refer to the
same EFI variable, do EFI variable merge, otherwise, do
EFI variable combination.
Contributed-under: TianoCore Contribution Agreement 1.1
Signed-off-by: Bob Feng <bob.c.feng@intel.com>
Cc: Liming Gao <liming.gao@intel.com>
Reviewed-by: Liming Gao <liming.gao@intel.com>
Replace dict with OrderedDict for PCD so that
the pcd list has same order.
Contributed-under: TianoCore Contribution Agreement 1.1
Signed-off-by: Bob Feng <bob.c.feng@intel.com>
Cc: Liming Gao <liming.gao@intel.com>
Reviewed-by: Liming Gao <liming.gao@intel.com>
For structure Pcd, the latter full assign value in commandLine should
override the former field assign value. For example in commandLine,
build --pcd Token.pcd.field="haha" --pcd Token.pcd=H"{0x01,0x02}",
the former field value "haha" will be ignored and overwrite by the latter
full value "{0x01,0x02}".
Contributed-under: TianoCore Contribution Agreement 1.1
Signed-off-by: ZhiqiangX Zhao <zhiqiangx.zhao@intel.com>
Cc: Liming Gao <liming.gao@intel.com>
Cc: Yonghong Zhu <yonghong.zhu@intel.com>
Cc: Bob Feng <bob.c.feng@intel.com>
Reviewed-by: Liming Gao <liming.gao@intel.com>
FlexibleFieldName was never used not set.
DefinitionPosition (file and line number) are recalculated
and never used outside the function. remove the saving of the
data.
Cc: Liming Gao <liming.gao@intel.com>
Cc: Yonghong Zhu <yonghong.zhu@intel.com>
Contributed-under: TianoCore Contribution Agreement 1.1
Signed-off-by: Jaben Carsey <jaben.carsey@intel.com>
Reviewed-by: Yonghong Zhu <yonghong.zhu@intel.com>
1) use namedtuple instead of custom class when apropriate
2) rename collections.OrderedDict to OrderedDict since we import it already
Cc: Liming Gao <liming.gao@intel.com>
Cc: Yonghong Zhu <yonghong.zhu@intel.com>
Contributed-under: TianoCore Contribution Agreement 1.1
Signed-off-by: Jaben Carsey <jaben.carsey@intel.com>
Reviewed-by: Yonghong Zhu <yonghong.zhu@intel.com>
1) use decorators
2) also change some private functions to public when all callers are
external
3) change external callers to use functions instead of directly
accessing private data.
Cc: Liming Gao <liming.gao@intel.com>
Cc: Yonghong Zhu <yonghong.zhu@intel.com>
Contributed-under: TianoCore Contribution Agreement 1.1
Signed-off-by: Jaben Carsey <jaben.carsey@intel.com>
Reviewed-by: Yonghong Zhu <yonghong.zhu@intel.com>
This patch align the boolean type PCD value's display in the build
report. Original it may display 0x0, also may use 0 for the same PCD.
Cc: Liming Gao <liming.gao@intel.com>
Cc: Yonghong Zhu <yonghong.zhu@intel.com>
Contributed-under: TianoCore Contribution Agreement 1.1
Signed-off-by: Zhiju.Fan <zhijux.fan@intel.com>
Reviewed-by: Yonghong Zhu <yonghong.zhu@intel.com>
Build tool should report warning if a platform
defines [DefaultStores] but forgets to defined
PcdNvStoreDefaultValueBuffer as PcdsDynamicExVpd in dsc file.
Contributed-under: TianoCore Contribution Agreement 1.1
Signed-off-by: ZhiqiangX Zhao <zhiqiangx.zhao@intel.com>
Cc: Liming Gao <liming.gao@intel.com>
Cc: Yonghong Zhu <yonghong.zhu@intel.com>
Cc: Bob Feng <bob.c.feng@intel.com>
Reviewed-by: Liming Gao <liming.gao@intel.com>
This patch is going to fix the issue that
The Pcd field value is override incorrectly when there
is no Pcd overall value assignment in Dsc file.
Contributed-under: TianoCore Contribution Agreement 1.1
Signed-off-by: Bob Feng <bob.c.feng@intel.com>
Cc: Liming Gao <liming.gao@intel.com>
Reviewed-by: Liming Gao <liming.gao@intel.com>
The case is user use 0x1} as a hex value for Pcd, it directly cause
tool report traceback info. This patch add more error info.
Cc: Liming Gao <liming.gao@intel.com>
Cc: Yonghong Zhu <yonghong.zhu@intel.com>
Contributed-under: TianoCore Contribution Agreement 1.1
Signed-off-by: Zhiju.Fan <zhijux.fan@intel.com>
Reviewed-by: Yonghong Zhu <yonghong.zhu@intel.com>
Defined a pcd in Ovmf.dec and used that pcd in AcpiPlatformDxe.inf,
then assign a value to that pcd from DSC, then build Ovmf platform
successfully. But this Pcd was wrongly listed into not used section
in the report.txt file.
Cc: Liming Gao <liming.gao@intel.com>
Cc: Yonghong Zhu <yonghong.zhu@intel.com>
Contributed-under: TianoCore Contribution Agreement 1.1
Signed-off-by: Zhiju.Fan <zhijux.fan@intel.com>
Reviewed-by: Yonghong Zhu <yonghong.zhu@intel.com>
1. Not append trailing zero for PcdValue
2. make sure the point to Variable Name in PCD
DataBase 2 bytes aligned.
Contributed-under: TianoCore Contribution Agreement 1.1
Signed-off-by: Bob Feng <bob.c.feng@intel.com>
Cc: Liming Gao <liming.gao@intel.com>
Reviewed-by: Liming Gao <liming.gao@intel.com>
Fixed the pcd value override issue when Dynamic Pcd is from
command line but is not list in Dsc file.
Contributed-under: TianoCore Contribution Agreement 1.1
Signed-off-by: Bob Feng <bob.c.feng@intel.com>
Cc: Liming Gao <liming.gao@intel.com>
Reviewed-by: Liming Gao <liming.gao@intel.com>
IsSupportedArch and IsBinaryModule return the same value under the same
curcimstances. Remove newer one with fewer callers and send them to the
other function.
Cc: Yonghong Zhu <yonghong.zhu@intel.com>
Cc: Liming Gao <liming.gao@intel.com>
Contributed-under: TianoCore Contribution Agreement 1.1
Signed-off-by: Jaben Carsey <jaben.carsey@intel.com>
Reviewed-by: Yonghong Zhu <yonghong.zhu@intel.com>
current use (0x41>=~0x0&0x41|0x0) as Pcd value cause build failure
because the ~ is not correctly recognized.
Contributed-under: TianoCore Contribution Agreement 1.1
Signed-off-by: Yonghong Zhu <yonghong.zhu@intel.com>
Reviewed-by: Liming Gao <liming.gao@intel.com>