lemp9: lower maximum fan speed
This commit is contained in:
parent
357fae86fc
commit
53d4c31798
@ -35,10 +35,10 @@ struct FanPoint {
|
||||
|
||||
// Fan curve with temperature in degrees C, duty cycle in percent
|
||||
struct FanPoint __code FAN_POINTS[] = {
|
||||
FAN_POINT(65, 40),
|
||||
FAN_POINT(70, 55),
|
||||
FAN_POINT(75, 75),
|
||||
FAN_POINT(80, 100)
|
||||
FAN_POINT(70, 40),
|
||||
FAN_POINT(75, 50),
|
||||
FAN_POINT(80, 60),
|
||||
FAN_POINT(90, 60)
|
||||
};
|
||||
|
||||
// Get duty cycle based on temperature, adapted from
|
||||
|