mb/samsung/stumpy: Set initial fan PWM to 30%
Recent changes to the ITE 8772F SIO code caused the initial fan PWM to change from 0 to 50%; set it to 30% to reduce fan noise while still providing some temp control before the OS/ACPI takes over. TEST=build/boot stumpy to payload, verify fan noise is negligible. Change-Id: I287e46202ee1c112d1da63c0d8b7889958e3807e Signed-off-by: Matt DeVillier <matt.devillier@gmail.com> Reviewed-on: https://review.coreboot.org/c/coreboot/+/81514 Reviewed-by: Varshit Pandya <pandyavarshit@gmail.com> Tested-by: build bot (Jenkins) <no-reply@coreboot.org> Reviewed-by: Nico Huber <nico.h@gmx.de>
This commit is contained in:
committed by
Nico Huber
parent
b8c451e375
commit
b40b6ff53e
@ -91,6 +91,7 @@ chip northbridge/intel/sandybridge
|
||||
register "TMPIN3.mode" = "THERMAL_PECI"
|
||||
# Enable FAN3
|
||||
register "FAN3.mode" = "FAN_SMART_SOFTWARE"
|
||||
register "FAN3.smart.pwm_start" = "30"
|
||||
|
||||
device pnp 2e.0 off end # FDC
|
||||
device pnp 2e.1 on # Serial Port 1
|
||||
|
Reference in New Issue
Block a user