Ensure smart charger uses new input current limits when detected
This commit is contained in:
@ -158,7 +158,9 @@ void usbpd_event(void) {
|
||||
if (next_input_current != battery_charger_input_current) {
|
||||
battery_charger_input_current = next_input_current;
|
||||
DEBUG("CHARGER LIMIT %d mA\n", battery_charger_input_current);
|
||||
//TODO: update smart charger
|
||||
|
||||
// Disable smart charger so it is reconfigured with the new limit
|
||||
battery_charger_disable();
|
||||
}
|
||||
}
|
||||
|
||||
|
Reference in New Issue
Block a user